Planning & Design

Architectural Project Development

The work of developing a parking structure's architectural, structural and MEP designs in compliance with regulations and standards.

How many vehicles a parking facility can hold is determined not only by the size of the site but by how that site is laid out. With the right column grid and parking angle, the same floor area can safely accommodate far more vehicles. The architectural project is the stage that creates this difference. The feasibility study tells you how large a facility you need; the architectural project turns that capacity into a buildable structure.

Park Expert treats the architectural project not as a single drawing but as a process in which the architectural, structural, electrical and mechanical disciplines move forward together. The goal is not merely to produce a code-compliant design, but to design a parking facility that runs efficiently on site, is safe, and keeps costs under control.

Decisions made at this stage are the most expensive ones to reverse. The position of a column, the slope of a ramp or the height of a floor cannot be changed once the structure is up. That is why the architectural project is the critical threshold that sets both the capacity of the investment and its long-term operating cost. A well-conceived design generates more value from the same plot for years to come.

Parking architectural project floor plan and circulation
The floor plan resolves parking spaces, aisles and traffic flow in a single layout.

What a parking architectural project covers

The architectural project establishes the layout logic of the facility. The arrangement of parking spaces, aisle widths, entry and exit points, ramp configuration and pedestrian circulation are all defined at this stage. Every decision directly affects capacity and ease of use. Changing a single aisle width by just a few centimeters can alter both the number of vehicles per floor and maneuvering safety.

A good architectural project creates the shortest and safest path from the moment a vehicle enters the facility to the moment it parks. Blind spots, tight turns and unnecessary maneuvers are eliminated at this stage. The result is a better driver experience and a higher turnover rate for the facility.

The floor plan and the section are the two core drawings that validate these decisions. The floor plan shows parking spaces and horizontal flow, while the section verifies floor heights, ramp slopes and vertical transitions. No layout can be considered buildable unless these two drawings are consistent with each other. Park Expert produces both drawings together on the same model.

  • Parking space layout and choice of parking angle.
  • Dimensioning of aisles, ramps and maneuvering areas.
  • Location of entry, exit and payment points.
  • Pedestrian circulation, stair and elevator placement.
  • Accessible parking spaces and access for people with disabilities.

Legal basis and standards

A parking project is developed within a defined framework of regulations and standards. This framework is not arbitrary. Its dimensions and rules define the minimum requirements for a safe and usable parking facility.

The Turkish Parking Regulation (Otopark Yönetmeliği) sets the minimum number of parking spaces and general design rules. TS 10551 is the technical standard that defines parking space dimensions, aisle widths and ramp slopes. Zoning Law No. 3194 provides the zoning and permitting basis for the project. Park Expert develops the project in line with all three frameworks from the outset, minimizing the risk of rework at the permitting stage.

Compliance with standards is not just a legal obligation. The minimum dimensions in the regulation define whether a vehicle fits in a space and whether its doors can open without damaging the neighboring car. Aisle width determines whether a vehicle can park in a single maneuver. Ramp slope ensures that a vehicle can climb to the next level without scraping its underbody. When these dimensions are squeezed, the facility holds more vehicles on paper but becomes unusable in practice.

Parking architectural project section showing ramp and floor circulation
The section verifies floor heights, ramp slope and vertical circulation.

Design criteria

A parking project is not measured solely by how many vehicles it fits. Safety, accessibility and ease of use are the criteria that define the quality of the design. Park Expert considers these criteria from the very beginning of the design process. They deliver their full value when they are built into the initial layout decision rather than added later as corrections.

  • Safety

    Adequate lighting, clear sight lines, fire escape routes and separation of vehicles and pedestrians form the foundation of the design.

  • Accessibility

    Accessible parking spaces, ramp slopes and elevator access are planned according to the dimensions set out in the regulation.

  • Circulation efficiency

    Entries, exits and floor-to-floor transitions are designed so that they do not create congestion at peak hours.

  • Aesthetics and contextual fit

    Facade, material and landscaping decisions give the structure an appearance that fits its surroundings.

Integrating EV charging infrastructure

As electric vehicle adoption grows, charging infrastructure has become an integral part of any parking project. Current regulations require a minimum level of charging provision in newly built parking facilities. Adding this infrastructure later is both expensive and difficult.

Park Expert plans charging needs at the design stage. Electrical capacity, switchboard placement and cabling are designed so that charging units can be added in the future. This allows the facility to launch charging services without major renovation once demand grows. The same approach also gives the parking facility a new revenue stream.

When planning charging infrastructure, we calculate which spaces will have chargers, how many units will operate simultaneously, and whether the building's existing electrical capacity can support them. Poorly planned infrastructure leads either to an expensive investment that goes unused or to insufficient capacity. Correct sizing at the design stage eliminates both risks.

3D architectural render of a modern parking structure with sustainable design
A 3D render makes the building's massing and fit with its surroundings visible before construction.

Coordinating architectural, structural and MEP design

A parking project is never the work of a single discipline. Architectural layout, the structural load-bearing system and the electrical and mechanical systems all come together in the same building. When these disciplines work in isolation, a column ends up in the middle of a parking space or a ventilation duct reduces the clear floor height.

Park Expert runs these disciplines under a single coordination process. The column grid is aligned with the parking layout, MEP routes are defined early, and clashes are resolved at the design table rather than on site. This approach minimizes costly changes during construction. A clash discovered on site often means work stoppages, wasted materials and schedule delays; the same clash caught at the design table is just a drawing revision.

Another benefit of coordination is that the design stays aligned with operations. The needs of the team that will later run the facility, including camera positions, barrier placement and maintenance access, are taken into account at the design stage. As a result, the project is not only buildable but also efficient to operate.

Park Expert's design approach

As a company that both designs and operates parking facilities, Park Expert looks at every project through an operator's eyes. This experience weeds out solutions that look good on paper but cause problems on site. Design decisions are evaluated together with the revenue the facility will generate and the operating costs it will incur over its lifetime.

This integrated perspective turns the architectural project from a formality into a tool that increases the value of the investment. A well-conceived design means more capacity on the same plot, lower operating costs and a longer-lasting structure.

When the site is constrained, an architectural solution alone may not be enough. In such cases, mechanical and automated parking systems come into play. Park Expert also evaluates the choice between a conventional structure and a mechanical system at the design stage, taking into account the geometry of the site and the demand profile. This evaluation is also the starting point of automated parking design work.

Frequently asked questions

Is a parking architectural project the same as a structural project?

No. The architectural project defines the layout, dimensions and user flow. The structural project resolves the load-bearing system and structural safety. The two are developed together, in coordination with the electrical and mechanical designs.

Which standards govern a parking project?

The Turkish Parking Regulation sets the minimum number of parking spaces and general rules. TS 10551 defines parking space dimensions, aisle widths and ramp slopes. Zoning Law No. 3194 provides the zoning basis for the project.

Are accessible parking spaces mandatory?

Yes. The Turkish Parking Regulation requires a certain number of accessible parking spaces to be allocated based on total capacity. The size and location of these spaces are planned at the design stage.

Is EV charging infrastructure required in a new parking facility?

Current regulations require a minimum level of charging provision in newly built parking facilities. At the design stage, electrical capacity and cabling are planned so that charging units can be added later.

Can a parking design be adapted to an existing building?

Yes. By assessing the existing column grid, floor heights and ramp options, a parking layout suited to the building can be developed. Where space is limited, mechanical systems are also an option.

Get your parking project right from the start

Park Expert develops architectural, structural and MEP designs that comply with regulations and standards and are ready for operation. Talk to our team about your project.

Get a QuoteLicense Plate Recognition System Demo